Medcal N, Single Phase Network Analyzer.

Medcal N is an advanced network analyser, specially designed for measuring voltage quality.

Medcal N is made for Norwegian conditions and measures all parameters (single phase) according to FoL.

 

The instrument meets the requirements of EN50160 and is the first single-phase instrument capable of fully implementing the recommendations of the EN61000-4-7 harmonic measurement standard.
Unlike other network analyzers; MEDCAL N analyzes each cycle in the calculation of harmonic voltage amplitudes.

The instrument is very easy to configure and setup is done without external switches or settings. All changes are made quickly and easily in the accompanying Medcal Scope software.

Medcal N also has an advanced transient detector on the voltage channels.
All transients are timed and can be easily analyzed via graphical representation.
All events are logged and can be easily viewed afterwards; either via a measurement table with measurement values (spreadsheet) or a graphical presentation.

The user-friendly Medcal Scope software provides clear and detailed information about recorded measurement data.
Medcal Scope also has a built-in report generator, for generating a clear NVE report.

The instrument is supplied with a cable for communication, a sturdy transport case and software (download).


 

Features:

 

  • Channels: 3 (Phase-Phase/Phase-Earth/Phase-Earth)
  • Measurment value: True RMS
  • Rated Voltage: 230Vrms, 50Hz
  • Measurment Range: 75-255V
  • Communication: USB
  • Precision RMS: ±0.5%
  • Precision frequenzy: ±0,005Hz
  • Sampling frequenzy: 30kHz/channel (600 sampl./period)
  • Harmonic measurment: THD and 1.-50. individual
  • Measurment period (Block Size/Recording Interval): 1 sec - 60 min
  • Internal memory: 2MB
  • Power consumption: Max 5W
  • Temperature range: -20-+60ºC
  • External measurments: approx 120(L)x65(B)x40(H)mm
  • Weight: approx. 200g

 

Note regarding software!


For instruments with firmware 1.81 and newer: Must use Medcal Scope 4.3.3 or newer.
For instruments with firmware 1.76: must use Medcal Scope 4.2.83.